Solution: Wire, Overhead Conductor, Contact Wire Testing

Solution: Wire, Overhead Conductor, Contact Wire Testing

Dipl.Ing. (FH) Harald Langheinrich

Deutschstraße 10 1230 Wien Österreich

+43 664 60454 6808

Send email

TVFA TÜV AUSTRIA GMBH

Region: Österreich

Deutschstraße 10 1230 Wien Österreich

+43 1 6650 600

Send email

Wire, Overhead conductor

Accreditation

In which region do you need this solution?

  • All regions

"Our services for over-head line conductors, wire ropes, high-voltage power lines, crane systems, lift installations and cableway systems."

We make cables safer. With our test methods and our expertise, we ensure the quality of over-head line conductors and wire ropes in general to guarantee safety for high-voltage power lines as well as for crane systems, lift installations and cableway systems.

Overhead line conductors, light-wave cables (OPGW, OPPC)

  • Tensile tests in accordance with EN 50182, including determination of the elastic modulus
  • Product certifications according to customer specifications
  • Clamping lengths up to 50 m, heating up to 220 °C
  • Creep tests in accordance with EN 61395
  • Measuring of thermal expansion coefficients and transition points of high-temperature overhead line conductors according to user guidelines
  • Single-wire tests in accordance with EN 50182
  • Vibration test according to user guidelines
  • Temperature-change tests in accordance with EN 61284

Steel cables

  • Tensile tests up to 10 MN, clamping lengths up to 50 m
  • Determination of the elastic modulus
  • Single-wire tests (tensile testing, bending testing, torsion testing, wind testing)
  • Wire ropes & cableway cables in accordance with DSB 80, ÖNORM M 9500
  • Magnetic rope testing MRT

Contact wire testing capabilities

TÜV AUSTRIA TVFA performs approval tests and product certifications according to customer specifications.

This includes clamping lengths up to 50m, heating up to 220°C, measuring of thermal expansion coefficients and transition points, vibration tests and damage analyses of cables and wires in accordance with German standard VDI 3822.

"*" indicates required fields

Land*
Address
This field is for validation purposes and should be left unchanged.

I am tami

Are you here for the first time? I will be happy to help you find your way around.

Check certificate

Find a solution

Submit science award

Check certificate

  • Person Certificate

  • Product Certificate

  • System Certificate

  • Verification of Conformity

Enter the data and check a certificate

Find a solution

WiPreis einreichen

WiPreis submit

"*" indicates required fields

1
2
3
4
First, please select in which category you would like to submit*

You cannot copy content of this page